This includes the 1756-EWEB and 1756-EWEBK modules. Allen-Bradley 1734-AENT EtherNet/IP Twisted Pair Media I/O Adapter 24V DC, Series A 10612598290434 UPP Ser A. It has LED indicators that show the adapter, Point BUS, and network statuses. It has a AENT1734 Module. If you dont wish to use our Priority Service, this service is optional and can be unselected from the Order Summary Box in our Checkout page. Set the chassis size to "2", for the AENT and the one expansion module. 9 out of 5 stars based on 8 product ratings. You must use Series C POINT I/O modules with the 1734-AENT adapter. Catalog Numbers 1734-FPD, 1734-FPDK, Series B Catalog numbers with the suffix ‘K’ are conformal coated and their specifications are the same as non-conformal coated catalogs. of Installation of this system we are facing Problem in above mentioned Module. If the item is not as described, you will have a full refund including all. 012 is currently installed, downgrading the1734-AENT B 5. Mfr. We found out that some of them are subject to radio interference. 1734-OE2C/C. Series A or Series B POINT I/O modules do not work with 1734-AENT EtherNet/IP Adapters (does not apply to POINTGuard modules). This release provides security and performance enhancements. 021 1734-AENTR (series C) 7. 013. Try our online PLC Simulator- FREE. The module supports half-duplex and full-duplex 10 Mbit or 100 Mbit operation. This release provides security and performance enhancements. Our Bulletin 1734 POINT I/O™ modules offer digital, analog, and specialty I/O, as well as POINT Guard safety-rated I/O, with one to eight points per module. A-B 1734-AENTR – Wooindustry. 1734-OE2C/C. User Manual. Supporting protocol for ASI. How to assign an IP address to an Allen Bradley 1734-AENT Point I/O module. 18 1734 POINT I/O EtherNet/IP Adapter . 1734-IN040. Point I-O 1734 Series . • Actual number of modules can vary. 1734-AENT series B and series C; 1734-AENTR series B and series C; 1738-AENT series B; 1738-AENTR series B; When ControlFLASH™ is used to update the adapter firmware, select the adapter from Node 1 as shown in the following example. PLC Hardware: Allen-Bradley 1734-AENTR 2-Port EtherNet/IP TP I/O. Allen-bradley rockwell automation 1734-aent user manual pdf downloadAllen-bradley 1771-ofe. Product Notice 2022-05-001 - Allen-Bradley POINT Guard I/O 1734-IB8S/B, 1734-IB8SK/B Intermittent Connection Fault. Implicit Protected Mode is a security enhancement in the Adapter level that helps prevent unauthorized configuration changes that can affect system behavior and cause unintended and. Installation Instructions. Series A or Series B POINT I/O modules will not work with 1734-AENT EtherNet/IP Adapters (does not apply to POINTGuard modules). 1734-AENT Allen-Bradley * Actual product may vary from image. All of my indicator lights are solid green (good) except for the network status light which is flashing green. They need to be in the 192. Find a Distributor. 1734-IB8S and 1734-OB8S modules, series A and B, are certified to IEC 61508 Edition 2. (1738-AENT, Series B) user manual. Implicit Protected Mode is a security enhancement in the Adapter level that helps prevent unauthorized configuration changes that can affect system behavior and cause unintended and. The 1734-AENT is a 1734 POINT I/O EtherNet/IP Adapter that is Brand:ed and manufactured by Allen-Bradley and Rockwell Automation. 1734-AENT (Series A) 3. POINT I/O Terminal Bases: Selection, Compatibility & Internal Wiring. Catalog Number 1734-AENT (series B) These release notes describe version information for 1734-AENT, version 5. 0, the Gateway at 0. Read this document before using a POINT I/O™ or ArmorPOINT® I/O EtherNet/IP adapter. 5754737 1734-AENT. In addition to viewing DVDs, one can play 3D video games and use enhanced DVD navigational tools such as zoom and smooth scanning of DVD playback. 1734-OB2E Series B Help LIVE PLC Questions And Answers30V (continuous), Basic Insulation Type, Ethernet to Backplane, USB to Backplane, and USB to Ethernet (Applies only to these modules/series: 1756-EN2T/D, 1756-EN2TR/C,1756-EN3TR/B), Type tested at 980V AC for 60 s. Most of1734-AENT/C Ethernet Adapter, 1734-AENTR/C Ethernet Adapter Network(s) EtherNet/IP Distinctive CIP Services N/A Device Profile Communications Adapter: 0x0C. SNMP Password and MIB Configuration. 1734-AENT, Series B; 1734-AENTR, Series B; 1734-AENT, Series C; 1734-AENTR, Series C. This release provides security and performance enhancements. The 1734-AENT series B can replace a series A adapter. Installation Instructions. 1734-OE2C/C. The screen captures shown in this manual are pictures of the software’s actual screens. $295. The 1734-AENT Series B module has an operating temperature range. 1734-IR2/C. Installing the Add-On Profile for the 1734-AENT Series B will make the module available in RSLogix 5000. 1734-AENT/R Series B flashing red POINTBus Status. my question is if it will work on my system I noticed that on the web ip page that on the network configuration page under gateway. Implicit Protected Mode is a security enhancement in the Adapter level that helps prevent unauthorized configuration changes that can affect system behavior and cause unintended and unforeseen. Installation Instructions. The 1756-ENBT module should have the revision 4. 884. User Manual. Please review the product. Installation Instructions. 00. Among the things that it shows installed is "Rockwell Automation 1734-AENT Ethernet Adapter Module Profile version 8. Once you've set up the module to your desired IP. It also can 10612598205223 UPP Ser D. 1734 Ob8s Wiring Diagram - One Layer Check Details 1734-8cfg Wiring Diagram Check Details PLC Hardware: Allen-Bradley 1734-OB8E POINT I/O 24V DC 8-Ch Output Module. 011 or 3. $295. or Best Offer. 1734 AENT Series B LIVE PLC Questions And Answers1734-AENT series B and series C; 1734-AENTR series B and series C; 1738-AENT series B; 1738-AENTR series B; The following web server anomalies can occur due to improper validation and authentication: Malicious code can be executed in the web browser due to cross-site scripting. This list includes substantive updates only and is not intended to reflect. EtherNet/IP Dual-Port adaptor module. 4. 1794-AENTR Series A: Versions 2. POINT I/O 2 Port Ethernet Adapter 5 Publication 1734-IN040B-EN-P - December 2009 WARNING When you connect or disconnect the Removable Terminal Block (RTB) with field side power applied, an electrica l arc can occur. Rockwell 1734-AENT series A to Series C. Is a series A module interchangeable with a series B? I currently use a Series B but the card is failing. from United States. htm[8/29/2016 4:43:01 PM] ·RSLogix 5000 Enterprise Series (Multiple Revision Support Phase II) V10. 0/16 is a private network everywhere. The 1734-AENT Series B is not a drop-in replacement for the Series A; older ControlLogix might need firmware upgrades, or need electronic keying disabled for compatibility. SNMP Password and MIB Configuration. Surplus Open Allen Bradley 1734-AENT Series B ENet/IP TP Media I/O Adapter 24V. In this mode, the subnet mask is fixed at 255. 1734-IN040. page ATTENTION: The 1734-AENTR and 1738-AENTR, Series A, POINT I/O and ArmorPOINT I/O dual port EtherNet/IP adapters with 3. 1734-AENT, Series B; 1734-AENTR, Series B; 1734-AENT, Series C; 1734-AENTR, Series C. The following versions of select Input/Output Modules from Rockwell Automation are affected: 1734-AENT/1734-AENTR Series C: Versions 7. ALLEN BRADLEY. 2 Refer to Create Module I/O Configuration on page 15 to configure the ILX34-Installation Instructions. 00: 5: 1734-AENT/A: RA: SOP: Allen-Bradley 1734-AENT EtherNet/IP TP Media I/O Adapter 24V DC, Series A: $352. norteamericano 146 Rango de temperatura de funcionamiento 147 Especificación de inmunidad RF radiada 147. 012 firmware should not be ControlFlash updated with any earlier firmware revision. Series A or B POINT I/O modules will not work with this adapter. 10. It has 24 Volts DC Input Voltage Rating and a Inrush Current of 6 A max for 10 ms with the following. A. 5962. To select one or more products from your search listing, you have the following options: To select the latest version, just double click on a product. Add the POINT I/O Adapter to the I/O Configuration. Current response time: 18 Minutes 52 Seconds1734-AENT, 1734-AENTR, 1769-AENTR, 1794-AENT, 20-COMM-E, 22-COMM-E, 20-750-ENETR Embedded Switches 1783-ETAP, 1783-ETAP1F, 1783-ETAP2 User Manual Original Instructions IMPORTANT This manual has been replaced by EtherNet/IP Network Devices, publication ENET-UM006. Series C allows selection of firmware versions 6 or 7. Catalog Numbers: 1734-AENT, 1734-AENTK, 1734-AENTR, 1734-AENTRK, Series B and Series C. This allows the 1734-AENTR adapter to be used in a daisy-chain topology with the 1734-AENT profile used for the 1734-AENTR. PUBLICATION NUMBER. 9393. com - online owner manuals library. 1734-AENT series B and series C; 1734-AENTR series B and series C; 1738-AENT series B; 1738-AENTR series B; The following web server anomalies can occur due to improper validation and authentication: Malicious code can be executed in the web browser due to cross-site scripting. This release provides security and performance enhancements. I/O ADAPTER, ETHERNET/IP, TWISTED PAIR MEDIA, 24 VOLT DC, 10 AMP . Add-On Profile for 1734-AENT and 1734-AENTR Series C. item 7 Allen Bradley 1734-AENT Series A EtherNet/IP Adapter Point I/O Allen Bradley 1734-AENT Series A EtherNet/IP Adapter Point I/O. 83 Routeco stock: 48 - Available now Add to basket Pricing/Availability request. Check Details 1734 aent fabricado radwell. (1) From version 21 onwards, RSLogix 5000 is known as Logix Designer. 1734-AENTR Series B, update to firmware Version 5. Any help would be greatly appreciated. This release provides security and performance enhancements. Implicit Protected Mode is a security enhancement in the Adapter level that helps prevent unauthorized configuration changes that can affect system behavior and cause unintended and unforeseen. Buy Surplus As Low As. 018 ALLEN BRADLEY 1734ANET. This allows the 1734-AENTR adapter to be used in a daisy-chain topology with the 1734-AENT profile used for the 1734-AENTR. $295. $295. Difference in 16#0203 and 16#0204. 1734-TB, -TBS, -TB3 and -TB3S Specifications Out 0 Out 1 Out 1 Out 0 CC V V Load Load 42014 V = 12/24V dc, C = Common Field power is supplied from power bus. Hold the `Ctrl` key down to select multiple items and then click `MOVE SELECTIONS` to finalize your selections. So click the "Select Files" on the line for the AOPs. 10. Buy 1734-AENT / 1734-AENT Allen Bradley Ethernet Ip Adapter from Distributor Santa Clara Systems. 1794-AENT Adapter FLEX I/O EtherNet/IP Adapter Installation Instructions 1794-IN082. 10. 002. 1734-AENT Allen Bradley Point I/O Ethernet IP Adapter Ser. Registro Italiano Navale. Find more technical documentation for this product in the Technical Documentation Center . That setting is supposed to tell the module to act as a Series A module. Select Files Firmware Only. 018 (released 8/2020). 00. If you need a specific series relating to 1734-AENT, we probably have it. 1734-aent series b user manual advertising rolls page 2 of 230 advertisements Thank you for your participation! * Your assessment is very important for improving the work of artificial intelligence, consisting of the content of this Project Rockwell Automation Publication 1734-UM018B-EN-P – October 2013 55 Configure the Adapter for Direct Connection and Rack. Representative Rendering, Not The Actual Product. 8 Rockwell Automation. 168. 3 View Dimension Drawings (3D Format) Catalog Number. C $144. Catalog Numbers 1734-OB2, 1734-OB4, 1734-OB4K, 1734-OB8, 1734-OB8K, Series C Catalog numbers with the suffix ‘K’ are conformal coated and their specifications are the same as non-conformal coated catalogs. 1734-IB8S and 1734-OB8S modules, series A and B, are certified to IEC 61508 Edition 2. It has a maximum expansion I/O capacity of 63 modules and supports up to 31 direct connections and 5 rack-optimization. 04-1985, Class G1, G2, and G3 environments; CEI IEC. If you need a specific series relating to 1734-OB8S, we probably have it. Free shipping. Find more technical documentation for this product in the Technical Documentation Center . Auto Catalog Replace The POINT I/O DeviceNet adapter supports the swapping of two identical modules connected to the adapter. 192. Select Files Firmware Only. I have two co-workers who have just gone to the field and the customer has the series B of these AENT BUT. This allows the 1734-AENTR adapter to be used in a daisy-chain topology with the 1734-AENT profile used. Summary of Changes This publication contains the following new or updated information. Installation Instructions. Industrial Automation Wiring and Grounding Guidelines, publication 1770-IN041. xxx, where xxx is the number you set. I've installed the 2 add-on profiles available from the Rockwell link but they are for version 4 and version 5 firmware. It has an open-style enclosure type and can be mounted horizontally or vertically. The 1794-AENT and 1794-AENTR connect FLEXI/O to Ethernet/IP. Series A or Series B POINT I/O modules do not work with 1734-AENT EtherNet/IP Adapters (does not apply to POINTGuard modules). 2. 1734-OE2C/C. The 1734-AENT contains status indicators for module, network, and POINTBus status,. Rockwell Automation took over Allen Bradley in 1985 and now employs around 21,000 and has staff in over 80 countries worldwide. 00 (V9. 00: 1: 1734-AENT/C: RA: SOP: Allen-Bradley 1734-AENT. Refer to publication 1734-UM011, POINT I/O EtherNet/IP Adapter User Manual, for more information. Please review the product label to check for the certifications your specific product carries. EtherNet/IP Twisted Pair Media I/O Adapter 24V DC. This exposes the backplane and power connections. $313. 884. if you are trying to dump power for some reason, you want a FPS not an EP24DC. Buy 1734-AENT / 1734-AENT Allen Bradley Ethernet Ip Adapter from Distributor Santa Clara Systems. Worldwide Shipping available. 1734 POINT I/O EtherNet/IP Adapters User Manual, publication 1734-UM018 Describes how to install, wire, configure, troubleshoot, and use a 1734-AENT series C adapter. Important User Information. THEN, you can search for the correct AOP. Mecha wiring: 1734 aentr wiring diagramAllen-bradley 1734-aentr manuals 1734 wiring aent manualzzAllen bradley point io manual. Topic Page About This Publication 1 Before You Begin 2 ATTENTION: You must only use Series C, and above, POINT I/O modules with 1734-AENT and 1734-AENTR EtherNet/IP Adapters. Customers are encouraged to remove references to the affected product (s). Please DON'T use it for advertising, etc. Although you will need to use the method above to set a public IP address on your module; the preferred method & approach is to use a private one. To select a specific product version. 12 months warranty. No link established. 800. This 1734 adapter is designed and manufactured by Allen. 1734 AENT Series B:. In the last week it has "crashed" three times. 9. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1. 00: 1: 1734-AENT/A: RA: UPP: Allen-Bradley 1734-AENT EtherNet/IP TP Media I/O Adapter. It has an input voltage rating of 24VDC nominal with voltage range of 10-28. Mô-đun I / O Series A và Series B POINT không tương thích . Installation Instructions. Allen bradley 1734 aent series b manualBradley allen 1734 aent plc ent Allen-bradley 1746 series i/o system installation instructions manualAllen-bradley 1391b series instruction. 201 and successfully disable it so static IP can be set to EPROM. I don't have the equipment here to verify for this. 24V DC. Please call or email us with your request. 0. 0 2. Allen-Bradley 1734-AENTR 2-Port EtherNet/IP Twisted Pair Media I/O Adapter 24V DC; Supports up to 20 Direct Connections and 5 Rack 10612598350145 UPP Ser B 1. Associated Products; Technical Specification. You must authenticate with your credentials before you can access the web server. Series A or Series B POINT I/O modules do not work with 1734-AENT and 1734-AENTR EtherNet/IP Adapters (does not apply to POINT Guard I/OTM modules). 01. 1734 AENT Series B: Dave37: LIVE PLC Questions And Answers: 1: June 23rd, 2014 03:10 PM: 1734 Aent design flaw? scott. Hydraulic Control Module, 2 LVDT Inputs, 2 Analog Outputs. Try our online PLC Simulator- FREE. , if a 1734-IB4 is in slot 3 and another 1734-IB4 is in slot 7, the two modules can be removed from the POINT system and the slot 3Find many great new & used options and get the best deals for Allen-Bradley 1734-aent Series B Network Adapter Module 137681 at the best online prices at eBay! Free shipping for many products!United States. Although you will need to use the method above to set a public IP address on your module; the preferred method & approach is to use a private one. Windows Meta-File (WMF) 1734-IB8. Surplus Never Used and Used 1734-OE4C by Allen Bradley In Stock today! We carry the entire Point I/O 1734 series. Series A or Series B POINT I/O modules will not work with 1734-AENT EtherNet/IP Adapters (does not apply to POINTGuard modules). Click on a product and then select a version. 1734-IN590. 5500 Order international:. Link established. EtherNet/IP 1734-AENT 1734-AENTR • 在控制器和 I/O 设备之间高速传输时间要求苛刻的数据 • 确定的、可重复的数据传递 • 介质冗余 • 控制器冗余 • 本质安全 ControlNet 1734-ACNR • 底层设备直接连接到工厂级控制器,不进行转接 • 按需求发送数据Allen-Bradley POINT Guard I/O 1734-IB8S/B, 1734-IB8SK/B Intermittent Connection Fault . $526. The 1734-AENT B 5. Allen bradley 1734 aent series b manual. Order toll free: 800. 019 and prior. TYPE. Remove the existing adapter from the DIN rail as follows: a. 00 Routeco stock: 266 - Available now. $295. The screen captures shown in this manual are pictures of the software’s actual screens. Allen-Bradley 1734-AENT EtherNet/IP Twisted Pair Media I/O Adapter 24V DC, Series C 10612598290434 SPP Ser C. Page. Many. Hello, I am new in PLCs, I hope you can help me. Important user information | Rockwell Automation 1734-AENTR, Series B Check Details 1734-aentr manual. 1734-aent pdf Install the adapter Ethernet manual user configuration ip network 1734 rockwell automation aentr. 1734-AENT (series B) 5. If you need a specific series relating to 1734-AENT, we probably have it. 10. Find a Distributor. 5962 Welcome!1734-AENT/R Series B flashing red POINTBus Status ; Add-On Profile for 1734-AENT and 1734-AENTR Series C ; Resetting the 1734-AENT(R) adapter to factory defaults, default password ; Using ControlFLASH to upgrade firmware on a 1734-AENT / 1738-AENT module; Rockwell Automation:Product Lifecycle Status and information1734-OE2C/C. Reset Back Cancel. There are two main reasons to set the IP within this range. 1734 ib8s manual Check Details 1734 Ob8s Wiring Diagram - One Layer Check Details 1734 ib8 manual1734 AENT Series B. The 1734-AENT Series A adapter module does not require network scheduling. 1734 AENT Series B: Dave37: LIVE PLC Questions And Answers: 1: June 23rd, 2014 03:10 PM: 1734 Aent design flaw? scott. 012 or later Logix controller 20 or later RSLogix 5000 software(1) 20 or later RSLinx software 2. Chassis size is the number of modules that will be inserted in the chassis. use 1734 POINT I/O modules over an EtherNet/IP network in a CompactLogix 5370 L1 control system. This includes the 1756-CNB and 1756-CNBK modules. 02". Manual. 00. aentr adapters ethernet dual port ip point 1738 series最大63%offクーポン ジョイショップ 店allen bradley 1734-adn device net adapter ser b. Installation Instructions. V10. 3. 168. In the Controller Organizer, right-click the 1734-AENT adapter and choose New. So the problem I am having is when I try to set static IP for a brand new 1734-AENTR/B using BootP-DHCP tool following steps: 1. Product Series: 1734* I/O Communication Interfaces; Get a Quote. 1734-IN026. 1734-AENT 24V DC EtherNet/IP Adapter 1734-AENTR 24V DC Dual Port Ethernet/IP Adapter 1734-ACNR 24V DC ControlNet Adapter 1734-ADN 1734-IA224V DC DeviceNet Adapter 1734-ADNX 1734-IA424V DC DeviceNet Adapter with Sub-net Expansion 1734-APB 1734-IM224V DC. 00: 1:. 1769-AENTR, 1783-ETAP, 1783-ETAP1F, 1783-ETAP2F, 1794-AENT, 20-COMM-E, 22-COMM-E, 1734-AENT, 1734-AENTR. 1738-AENTR series B adapter. Click here now to try it. Allen-Bradley 1734-IB4 POINT I/O 24V DC 4-Channel Sink Input Module, can be used with DeviceNet and PROFIBUS adapters. Check DetailsCatalog number 1734-AENTR, Series B. Try our online PLC Simulator- FREE. This list includes substantive updates only and is not intended to reflect all. Re-seating means physically removing a circuit board, I/O module, controller card, etc, and reinstalling it. ATTENTION: The Series C adapter requires an EDS file for RSLinx® and. 021. 1 AFFECTED PRODUCTS. About the Example Applications This manual presents two example applications that demonstrate the procedures for configuring and communicating with POINT I/O modules using the 1734-AENT adapter. Topic Page Summary of Changes 1 Overview 5 Install Your Adapter 5 Mount the Adapter on a DIN Rail 6 Mount on a Panel. It supports Ring, Star, and Tree Topology and transmission speed of 10/100 Mbits/s in Half or Full-Duplex mode. Registro Italiano Navale. The time now is 06:30 AM. More information on proper wiring and grounding techniques. This module serves as a bridge between the I/O module and the network. ATTENTION: The 1734-AENT and 1738-AENT, Series A, POINT I/O and ArmorPOINT I/O EtherNet/IP adapters with 3. 5962 Welcome! 1734-AENT/R Series B flashing red POINTBus Status ; Add-On Profile for 1734-AENT and 1734-AENTR Series C ; Resetting the 1734-AENT(R) adapter to factory defaults, default password ; Using ControlFLASH to upgrade firmware on a 1734-AENT / 1738-AENT module; Rockwell Automation:Product Lifecycle Status and information 1734-OE2C/C. Supporting protocol for CAN. If you need a specific series relating to 1734-IB8S, we probably have it. Allen-Bradley 1734-AENTR 2-Port EtherNet/IP Twisted Pair Media I/O Adapter 24V DC; Supports up to 20 Direct Connections and 5 Rack 10612598350145 UPP Ser B 1. $295. The 1734-AENTR adapters will accept I/O connections with electronic keying for the 1734-AENT. Rockwell Automation Publication 1734-UM001E-EN-P - July 2013 xiv Preface Additional Resources Refer to this table for a list of related 1734 products and documentation. Catalog Numbers: 1734-AENT, 1734-AENTK, 1734-AENTR, 1734-AENTRK, Series B and Series C. 1734-AENT. ALLEN BRADLEY. com. User Manual. The Allen-Bradley 1734-AENT is a POINT I/O Ethernet/IP Adapter Module. Add to basket Pricing/Availability request. See all 350 - listings for this product. Adapter POINT I/O DeviceNet adapter (1734-ADN and 1734-ADNX). Order international: +1 609. 40. 16#0127 Connection Request Error: Invalid Output Size Module Fault. Summary of Changes This publication contains the following new or updated information. The Allen-Bradley 1734-AENTR is a Point I/O Dual Ethernet communication module. 1734-AENT/B: RA: SSP: Allen-Bradley 1734-AENT EtherNet/IP TP Media I/O Adapter 24V DC, Series B: $319. RSLogix 5000 version 17 or greater must be used for the 1734-AENTR. Installing the Add-On Profile for the 1734-AENT Series B will make the module available in RSLogix 5000. 1734 aentr bradley allen representative radwell. 8V DC; Field side power requirements: 400 mA @ 24V DC (+20% = 28. this document contains confidential and proprietary information of rockwell automation, inc. 1734-IR2/C. 19. Setting the IP Address of the PointIO 1734-AENT Through Dial Switches. Rockwell Automation Publication 1734-UM018B-EN-E - October 2013. The VDC+ should be jumped to the FP+, and. POINT I/O. Allen-Bradley 1734-AENT EtherNet/IP Twisted Pair Media I/O Adapter 24V DC, Series A 10612598290434 SOP Ser A. Set 888 on rotary switches, power cycle, set 999, open BOOTP/DHCP Tool, the module should appear with MAC Address, choose and assign new IP Address, after - disable BOOTP/DHCP. This 1734 adapter is designed and manufactured by Allen-Bradley/Rockwell Automation. 00. The 1734-AENT Series B module supports DIN rail mounting by using the Removable Terminal Block (RTB), and it has a snap-in installation method that allows for easy and simplified field installation. About the Manufacturer. Reset Back Cancel. Order toll free: 800. Find more technical documentation for this product in the Technical Documentation Center . You have to replace all 3 because they are. The 1734-AENTR adapters will accept I/O connections with the electronic keying for the 1734-AENT. It now provides a drop-down option to select 1734-AENT Series A, B, or C. 4. The following versions of select Input/Output Modules from Rockwell Automation are affected: 1734-AENT/1734-AENTR Series C: Versions 7. maddox: LIVE PLC Questions And Answers: 2: April 18th, 2014 02:04 AM: 1734 Aent and Security modules: Tarlo: LIVE PLC Questions And Answers: 5: December 30th, 2011 01:37 PM: All times are GMT -4.